MGHome page

GWAS course

Course map

0 of 64 steps done

Start with step 0.1Install R

Saved in this browser only.

Step 1.8

Module 1 · From DNA to array data · step 8 of 11

1.8Where genetic data come from

In short

We compare arrays, sequencing and predicted genotypes, which estimate unmeasured DNA results using a reference group. We read what each source measures and misses so we can understand which questions its data can answer.

What you do

Read this page. There is no code to run.

Command

No code to run. This is a reading-only step.

You need

The array explanation at 1.2. No extra dataset is needed.

What we do

Reading, about 5 minutes. You can come back to it later.

Compare ways to measure genetic variation. This course uses simulated array data.

Why

A read (opens in a new tab) is a sequence measured from one DNA molecule. Sequencing (opens in a new tab) reads bases. An array (opens in a new tab) measures signals at selected sites instead. Depth (opens in a new tab) counts reads covering a base. Density (opens in a new tab) counts tested sites across a region. These are different quantities.

A targeted panel (opens in a new tab) tests selected genes or regions. An amplicon (opens in a new tab) is a DNA segment copied before sequencing. The exome (opens in a new tab) is the protein-coding part of the genome. Imputation (opens in a new tab) predicts unmeasured alleles using a reference group. Summary statistics (opens in a new tab) report group-level results instead of individual genotypes.

Costs below are relative for large research studies. They depend on sample numbers, preparation and analysis. They are not price quotes. A typical depth is a study design choice, not a guarantee for every base.

SourceWhat is measuredDensity or depthStrengthBlind spotRelative cost and typical use
Illumina Infinium Global Screening Array (GSA) and Global Diversity Array (GDA)Fluorescence at selected SNPsHundreds of thousands to a few million sites, depending on designMany samples at low costMost unselected and rare sites are not directly measuredLow; common-variant association
Thermo Fisher Axiom arraysProbe signals at selected sitesHundreds of thousands of sites or more, depending on designLarge studies and custom content; UK Biobank used AxiomContent and calling quality depend on designLow; population studies
Targeted panels and ampliconsReads from chosen regionsOften hundreds of reads per target baseDetailed measurements in selected genesRegions outside the panel are absent; copying can bias allele balance (opens in a new tab)Low to medium; focused research or clinical testing
Whole-exome sequencingReads from captured (opens in a new tab) coding regionsOften tens to over 100 reads per target baseMany rare coding variantsMost non-coding regions and some difficult exons are missedMedium; coding-variant studies
Short-read (opens in a new tab) whole-genome sequencing (opens in a new tab)Reads across the genomeAbout 30x is a common research designBroad measurement of common and rare variationRepeats and large rearrangements (opens in a new tab) can remain difficultHigh; discovery across the genome
Low-pass (opens in a new tab) whole-genome sequencing plus imputationSparse reads followed by predicted genotypesOften below a few reads per baseBroad coverage at lower sequencing costRare alleles and poorly represented ancestries can be harder to predictLow to medium; large cohorts with a suitable reference
Newer sequencing platforms: Roche SBX, Element AVITI, MGI/Complete Genomics DNBSEQ and UltimaDNA sequence from whole genomes or selected regionsGenome-wide or target coverage; depth is selected for the studyFast turnaround or high sample throughput, depending on the platformError patterns and difficult regions need platform-specific checksPlatform and batch dependent; large-scale sequencing
Oxford Nanopore (ONT) long readsElectrical signals converted to long sequencesDepth varies; reads can span many thousands of basesRepeats, large rearrangements, long-range context and native base modifications (opens in a new tab) such as 5mC (opens in a new tab)DNA quality, errors and analysis choices matterMedium to high; complex variation
PacBio high-fidelity (HiFi) long readsRepeated observations combined into accurate long sequencesDepth varies; reads often span many thousands of basesAccurate long reads, complex variation and native base modifications (opens in a new tab) such as 5mC (opens in a new tab)Preparation, DNA quality and cost constrain designsMedium to high; genome discovery
Imputed genotypesProbabilities inferred from measured data and a referenceOften millions of predicted variantsWider coverage without measuring every sitePredictions are uncertain and reference-dependentLow added analysis cost; association at untyped sites
Summary statisticsEffects and uncertainty from an association analysisOne row per tested variantShare results without sharing individual callsCannot recover each person's genotype or redo every modelLow storage cost; combining studies

Roche sequencing by expansion (SBX) is a single-molecule, nanopore-based (opens in a new tab) method: it reads a molecule through a tiny sensor opening. It is designed for speed. Roche describes reads up to about 1,500 bases with suitable sample preparation. Roche SBX (opens in a new tab), Element AVITI (opens in a new tab), MGI/Complete Genomics DNBSEQ (opens in a new tab) and Ultima (opens in a new tab) all feed workflows using standard formats. These include FASTQ (opens in a new tab) for reads and qualities, BAM/CRAM (opens in a new tab) for read records, and VCF (opens in a new tab) for variants. Alignment matches reads to a reference. Variant calling assigns alleles from the evidence.

Native base modifications (opens in a new tab) are chemical changes present on the original DNA. Methylation (opens in a new tab) adds a small chemical group. 5mC (opens in a new tab) means 5-methylcytosine, a modified C base. ONT (opens in a new tab) and PacBio HiFi (opens in a new tab) can detect it from native DNA with suitable analysis models. This adds information beyond the A, C, G and T sequence.

Official documentation: Illumina GSA (opens in a new tab), GDA (opens in a new tab), Thermo Fisher arrays (opens in a new tab), Roche SBX outputs (opens in a new tab), ONT output specifications (opens in a new tab) and PacBio HiFi (opens in a new tab).

References: Infinium, PMID 15838508 (opens in a new tab); Axiom, PMID 21565264 (opens in a new tab); HiFi, PMID 31406327 (opens in a new tab); UK Biobank, PMID 30305743 (opens in a new tab).

Expected result

Show the expected result

You can distinguish a measured array call, a sequence read and an imputed prediction. This course starts from array calls.

If something goes wrong

If something goes wrong

Do not compare array density with sequencing depth. They measure different things. Follow the glossary links before reading the table again.

Quick check

Would deeper sequencing of a small panel reveal variants everywhere in the genome?

Show the answer

No. More depth improves measurements inside the targets. It does not add regions outside them.

Files created