Module 1 · From DNA to array data · step 8 of 11
1.8Where genetic data come from
In short
We compare arrays, sequencing and predicted genotypes, which estimate unmeasured DNA results using a reference group. We read what each source measures and misses so we can understand which questions its data can answer.
What you do
Command
No code to run. This is a reading-only step.
You need
The array explanation at 1.2. No extra dataset is needed.
What we do
Reading, about 5 minutes. You can come back to it later.
Compare ways to measure genetic variation. This course uses simulated array data.
Why
A read (opens in a new tab) is a sequence measured from one DNA molecule. Sequencing (opens in a new tab) reads bases. An array (opens in a new tab) measures signals at selected sites instead. Depth (opens in a new tab) counts reads covering a base. Density (opens in a new tab) counts tested sites across a region. These are different quantities.
A targeted panel (opens in a new tab) tests selected genes or regions. An amplicon (opens in a new tab) is a DNA segment copied before sequencing. The exome (opens in a new tab) is the protein-coding part of the genome. Imputation (opens in a new tab) predicts unmeasured alleles using a reference group. Summary statistics (opens in a new tab) report group-level results instead of individual genotypes.
Costs below are relative for large research studies. They depend on sample numbers, preparation and analysis. They are not price quotes. A typical depth is a study design choice, not a guarantee for every base.
| Source | What is measured | Density or depth | Strength | Blind spot | Relative cost and typical use |
|---|---|---|---|---|---|
| Illumina Infinium Global Screening Array (GSA) and Global Diversity Array (GDA) | Fluorescence at selected SNPs | Hundreds of thousands to a few million sites, depending on design | Many samples at low cost | Most unselected and rare sites are not directly measured | Low; common-variant association |
| Thermo Fisher Axiom arrays | Probe signals at selected sites | Hundreds of thousands of sites or more, depending on design | Large studies and custom content; UK Biobank used Axiom | Content and calling quality depend on design | Low; population studies |
| Targeted panels and amplicons | Reads from chosen regions | Often hundreds of reads per target base | Detailed measurements in selected genes | Regions outside the panel are absent; copying can bias allele balance (opens in a new tab) | Low to medium; focused research or clinical testing |
| Whole-exome sequencing | Reads from captured (opens in a new tab) coding regions | Often tens to over 100 reads per target base | Many rare coding variants | Most non-coding regions and some difficult exons are missed | Medium; coding-variant studies |
| Short-read (opens in a new tab) whole-genome sequencing (opens in a new tab) | Reads across the genome | About 30x is a common research design | Broad measurement of common and rare variation | Repeats and large rearrangements (opens in a new tab) can remain difficult | High; discovery across the genome |
| Low-pass (opens in a new tab) whole-genome sequencing plus imputation | Sparse reads followed by predicted genotypes | Often below a few reads per base | Broad coverage at lower sequencing cost | Rare alleles and poorly represented ancestries can be harder to predict | Low to medium; large cohorts with a suitable reference |
| Newer sequencing platforms: Roche SBX, Element AVITI, MGI/Complete Genomics DNBSEQ and Ultima | DNA sequence from whole genomes or selected regions | Genome-wide or target coverage; depth is selected for the study | Fast turnaround or high sample throughput, depending on the platform | Error patterns and difficult regions need platform-specific checks | Platform and batch dependent; large-scale sequencing |
| Oxford Nanopore (ONT) long reads | Electrical signals converted to long sequences | Depth varies; reads can span many thousands of bases | Repeats, large rearrangements, long-range context and native base modifications (opens in a new tab) such as 5mC (opens in a new tab) | DNA quality, errors and analysis choices matter | Medium to high; complex variation |
| PacBio high-fidelity (HiFi) long reads | Repeated observations combined into accurate long sequences | Depth varies; reads often span many thousands of bases | Accurate long reads, complex variation and native base modifications (opens in a new tab) such as 5mC (opens in a new tab) | Preparation, DNA quality and cost constrain designs | Medium to high; genome discovery |
| Imputed genotypes | Probabilities inferred from measured data and a reference | Often millions of predicted variants | Wider coverage without measuring every site | Predictions are uncertain and reference-dependent | Low added analysis cost; association at untyped sites |
| Summary statistics | Effects and uncertainty from an association analysis | One row per tested variant | Share results without sharing individual calls | Cannot recover each person's genotype or redo every model | Low storage cost; combining studies |
Roche sequencing by expansion (SBX) is a single-molecule, nanopore-based (opens in a new tab) method: it reads a molecule through a tiny sensor opening. It is designed for speed. Roche describes reads up to about 1,500 bases with suitable sample preparation. Roche SBX (opens in a new tab), Element AVITI (opens in a new tab), MGI/Complete Genomics DNBSEQ (opens in a new tab) and Ultima (opens in a new tab) all feed workflows using standard formats. These include FASTQ (opens in a new tab) for reads and qualities, BAM/CRAM (opens in a new tab) for read records, and VCF (opens in a new tab) for variants. Alignment matches reads to a reference. Variant calling assigns alleles from the evidence.
Native base modifications (opens in a new tab) are chemical changes present on the original DNA. Methylation (opens in a new tab) adds a small chemical group. 5mC (opens in a new tab) means 5-methylcytosine, a modified C base. ONT (opens in a new tab) and PacBio HiFi (opens in a new tab) can detect it from native DNA with suitable analysis models. This adds information beyond the A, C, G and T sequence.
Official documentation: Illumina GSA (opens in a new tab), GDA (opens in a new tab), Thermo Fisher arrays (opens in a new tab), Roche SBX outputs (opens in a new tab), ONT output specifications (opens in a new tab) and PacBio HiFi (opens in a new tab).
References: Infinium, PMID 15838508 (opens in a new tab); Axiom, PMID 21565264 (opens in a new tab); HiFi, PMID 31406327 (opens in a new tab); UK Biobank, PMID 30305743 (opens in a new tab).
Expected result
Show the expected result
You can distinguish a measured array call, a sequence read and an imputed prediction. This course starts from array calls.
If something goes wrong
If something goes wrong
Do not compare array density with sequencing depth. They measure different things. Follow the glossary links before reading the table again.
Quick check
Would deeper sequencing of a small panel reveal variants everywhere in the genome?
Show the answer
No. More depth improves measurements inside the targets. It does not add regions outside them.
Files created
None.